logo_txt.jpg (15605 bytes)

Home ] Up ] Ivan's Aerie ] Lauren's Lair ] Boppa's Bailiwick ] Rick's Redoubt ] Suzi's Soufle ] Our Garden ] Norwegian Roots ]


Up ]

© Robert Midthun 1998

CIPP LOAD TESTS - ACTUAL DEFLECTIONS vs ULTIMATE
ULTIMATE PERCENT OF
AGENCY & TEST NAME CIPCP DIA. WALL THICK. CONCRETE LOAD (LB./LF) MEAS. DEFLECT. DIA.SQD./1200 T ULTIMATE
(Inches) (Inches) (f'c - 28 da.) (Lbs./l.f.) (Inches) (Inches) USED
L.A.CO.FLOOD CONT. DIST. 48 5 4000 psi 7,788 0.0153 0.38 3.98%
Private Drain No. 889 :
CITY OF PHOENIX, AZ, 54 5.5 3000 psi 15,635 0.023 0.44 5.21%
Joint Test w/Salt River Proj
SACRAMENTO CO., CALIF. 72 7 3000 psi 18,070 0.03 0.62 4.86%
22ND AVE. TEST SITE
SACRAMENTO CO., CALIF. 72 7 3000 psi 34,500 0.04 0.62 6.48%
22ND AVE. TEST SITE
SACRAMENTO CO., CALIF. 84 8 0.003 0.74 0.41%
Fruitridge Dr.Ass.Dist.
TEXAS INDUSTRIES 96 9 4-5,000 psi 51,250 0.034 0.85 3.98%
Pilot Test Program
AVCO FINANCIAL 120 12 4-5,000 psi 25277 0.0075 1.00 0.75%
Coastal Phase One - Or.Co.
DATA FROM ACTUAL FEILD TESTS BY ABOVE AGENCIES